About Reverse Power Relay TE 800
We are counted among the trustworthy manufacturers of Reverse Power Relay TE 800 for our highly honoured clients. It monitors the power flowing in the phases. The direction of the power is checked. The relay monitors current flowing in the B phase. This current is squared with the voltage in RY phase and motoring condition detected. Power sensed of our Reverse Power Relay TE 800 is compared to a reference and a timer is triggered above limit. Timer can be set 0-10 sec. Contacts changeover occurs on time out and an LED indication signals closure.
RYB SENSING Reverse Power - 6 - 10 %
Size : 70 x 60 x 110 mm
Comprehensive Generator ProtectionThe TE 800 Reverse Power Relay plays a crucial role in protecting generators by detecting and preventing reverse power flow. This relay is installed on the generator panel, continuously monitoring power direction to quickly disconnect the generator if reverse power is detected. Its fast actuation and robust design help prevent backfeeding and damage, making it indispensable for generator reliability and safety.
Versatility and Durable ConstructionWith selectable coil voltages and a rugged construction, the TE 800 is engineered for a broad range of generator setups. Its compact 96 x 96 x 75 mm panel-mountable body, along with a weight of approximately 250g, ensures easy integration into standard control panels. The relay is built to last, featuring an extensive mechanical lifespan and high resistance to insulation breakdown.
FAQs of Reverse Power Relay TE 800:
Q: How does the TE 800 Reverse Power Relay protect generators?
A: The TE 800 detects reverse power flow, which indicates that power is being fed back into the generator instead of being generated. Upon detection, the relay promptly operates to disconnect the generator, preventing potential damage and ensuring safe operation.
Q: What is the typical operate time of the TE 800 relay?
A: The TE 800 is designed with a typical operate time of 200 milliseconds, offering fast response to reverse power events and enhancing the protection of generator systems.
Q: When should you use the TE 800 Reverse Power Relay?
A: The relay should be used in installations where generators are paralleled with a grid or other generators, and there is a risk of reverse power flow. It is particularly beneficial during synchronization or when load fluctuations are expected.
Q: Where can the TE 800 relay be installed?
A: The TE 800 is suited for standard panel mounting, with a footprint of 96 x 96 x 75 mm, making it ideal for integration into generator control panels in industrial, commercial, and utility environments.
Q: What are the main benefits of using the TE 800 in generator setups?
A: The primary benefits include reliable detection of reverse power, fast response time to minimize equipment risk, long mechanical lifespan, and easy panel integration, ensuring enhanced safety and longevity for generator systems.
Q: What is the process for integrating the TE 800 relay into a generator panel?
A: To integrate the relay, mount it on the panel, connect the appropriate coil voltage (230V AC or 110V DC), and wire the SPDT contacts as per system requirements for reverse power disconnection. Ensure all installation standards and safety protocols are followed.